7.2.5 Using the direction detection of transponder with the People Counter
In combination with the People Counter a direction detection of the transponders could be per-
formed in that way, that only transponder will cause an alarm which move in the configured direc-
tion through the gate. This should reduce false alarms.
It is mandatory that the trigger cable described in
7.2.4 Using the trigger function of the
Gate People Counter
is connected to Input 2 of the reader and X4/TRG of the terminal
board, otherwise the direction mode will not work!
Step
Action
Note
1
Select „Configuration“
2
Select Peripheral Devices
– Gate People Counter
Set Direction Mode to the
needed alarm direction.
Select Peripheral Devices
- Filter
Set Time Limit before and
after Tag Detection.
e.g. 200x5ms =1000ms
Time should be not to
short or to long !
3
Confirm with „Apply“
7
Walk through the gate with
a valid transponder and
check the alarm direction.
At multiple gates with more than two antennas, it is mandatory that the correct number
order of the connected antennas, alarm LED and people counter with radar module must be
observed. Setup, Connecting and Configuration hints could be found in the Application
Note N61211-xe-ID-E-pdf.