OBID i-
scan
®
Installation
ID ISC.ANT1700/740-SLA/-SLB
FEIG ELECTRONIC GmbH
Page 33 of 66
M00210-2e-ID-B.doc
Step
Action
Note
6
Select „Function Unit
Command“ „Multiplexer“
„Channel Select“ activate
antenna 2.
„Cascade Level = 1“
„Output Channel of Input 1
= 2“
7
Set by clicking on „Send“.
8
Repeat step 3 to 5 for
antenna 2, 3, 4.
If the values are not met, check the following:
Are all cables pulled tight and do they make good contact?
Were the ring cores installed in the antenna cable?
Were the cables routed as specified?
Are other RFID systems installed nearby?
Are there large metal parts near the antenna (distance < 1.0 m)?
Are there devices nearby which may emit noise interferences (larger machines or wireless
devices)?
Are there interferences from the mains?
To determine which devices may be disturbing the gate, briefly disconnect them from the mains.