OBID i-
scan
®
Installation
ID ISC.ANT1700/740-SLA/-SLB
FEIG ELECTRONIC GmbH
Page 41 of 66
M00210-2e-ID-B.doc
5.5 Activating the Automatic Mode
The gate must be used in one of the Automatic Modes (Buffered Read, Notification
or Scan Mode) to get a maximum performance.
Which Mode is useful in your application, has to be defined in advance.
Here we describe the activation of the Buffered Read Mode.
Here the tags are read at maximum speed and the information is stored in the Reader’s ring buffer.
This data sets can be read by the host.
To activate „Buffered Read Mode“ proceed as follows:
Step
Action
Note
1
Select „Configuration“
2
Operation Mode:
„Mode“ - Buffered Read
Mode
„Data Selector“
-UID
-Antenna No
-Time
-Date
„Filter“
Set Transponder Valid
Time.
(e.g. 55 x 100ms)
3
Set clicking on „Apply“
Note:
The configuration of the Notification or Scan Mode are similar (See System Manual of the reader)
To test the function of the Gate in the Buffered Read Mode, the BRM Window of ISOStart or the
BRMDemo program can be used. See Siehe System Manual reader LR2000