![background image](http://html1.mh-extra.com/html/feig-electronic/id-isc-mr102/id-isc-mr102_manual_3890489106.webp)
Identification
Manual
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 106 of 153
H01113-4e-ID-B.docx
BANK_NR:
Defines the memory area on the transponder.
b00
reserved
b01
reserved
b10
reserved
b11
User memory bank
DB-ADR:
First block number from which security status is requested. First block number can be any
value between 0 and 255.
DB-N:
Number of Security data blocks to be read from the Transponder, starting at DB-ADR.
The maximum number of DB-N is 255.
ISO15693 ERROR:
ISO15693 ERROR code of Transponder response. This byte is only available if STATUS =
0x95. See:
ANNEX F: Transponder Error Codes
SEC-STATUS:
Block security status .
Note:
This command is only available for ISO15693 Transponders