H01113-4e-ID-B.docx
2. Data Transmission between OBID i
-scan
®
ID ISC.MR102 and Host
Different ways of data transmission between OBID i
-scan
®
Readers and host (terminal, PC) are
possible. The
ISO15693Host Commands
are used for the data exchange between Transponder
and host, whereas the
Configuration Commands
and the
Control
serves for adapting the Read-
er parameters to the individual range of applications. The following chart shows which method of
data transmission is supported by which interface:
interface
asynchronous
(RS232 / RS485)
USB
LAN
Configuration and control commands
ISO Host Commands
Scan-Mode
(HID)
-
Notification Mode
-
-
2.1. Configuration Commands and Control Commands
This method of data transmission is used for Reader configuration and the diagnosis via the asyn-
chronous interface or Ethernet Interface
The Reader-configuration parameters will be stored in the Reader memory. To store the current
configuration during a power down of the Reader the Reader-Configuration has to be stored in the
EEPROM. After power up the Reader reads the configuration out of the EEPROM.
The Reader control is immediately processed and the response from the Reader contains status or
data information of the control command.
Host (Terminal / PC / ....)
Reader
parameter- / control command
parameter received and stored / control
command processed
yes
no
status /
data
error status