![background image](http://html1.mh-extra.com/html/feig-electronic/id-isc-mr102/id-isc-mr102_manual_3890489135.webp)
Identification
Manual
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 135 of 153
H01113-4e-ID-B.docx
0x2C
Get Multiple Block Security
Status
-
-
-
-
0xA3
Inventory Read Multiple
Blocks
-
-
-
-
0xAB
Inventory Get System Infor-
mation
-
-
-
-
0xAC
Inventory Get Multiple Block
Security Status
-
-
-
-
0xA2
Write 2 Blocks
-
-
-
-
0xA3
Lock 2 Blocks
-
-
-
-
0xA4
Kill
(only Tag-it HFI Pro)
0xA5
WriteBlockPwd
(only Tag-it HFI Pro)
Note:
*
Reading of more than one block in non addressed mode is only possible, if parameter
“Read Mode” in CFG4 is set to “01: Single Read“.
**
The WR-OPTION will be set automatically by the FEIG Readers if the WR-OPTION pa-
rameter in “CFG4 General” is set to “00: automatically set”.
When using the “non-addressed” mode the WR-OPTION must be set manually to “WR-
OPTION = 1”.