Hex-value
Parameter Status
0x10
EEPROM-failure:
The EEPROM of the Reader is not able to be written on.
Before writing onto the EEPROM a faulty checksum of parameters has been detect-
ed.
0x11
Parameter-Range-Error:
The value range of the parameters was exceeded.
0x13
Login-Request:
Configuration access without having logged in to the Reader before.
0x14
Login-Error:
Login attempt with wrong password.
0x15
Read Protect:
The configuration block is reserved for future use.
0x16
Write Protect:
The configuration block is reserved for future use.
0x17
Firmware activation required:
The firmware must be activated first using ISOStart demo program and the command “Set
Firmware Upgrade”. The update code must be ordered by Feig Electronic.
1. Read the Device-ID using the command [0x66] Firmware version (Mode 0x80)
2. Send the Device-ID and the serial number of the reader to Feig Electronic
3. Write the upgrade code into the reader using the command [0x5F] Set Firmware Update
Hex-value
Interface Status
0x80
Unknown Command:
The Reader does not support the selected function.
0x81
Length-Error:
Protocol is too short or too long
0x82
Command not available:
Reader is set to a wrong mode
Command is not supported