![background image](http://html1.mh-extra.com/html/feig-electronic/id-isc-mr102/id-isc-mr102_manual_3890489146.webp)
Identification
Manual
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 146 of 153
H01113-4e-ID-B.docx
0x83
RF communication error:
This error indicates that there is an error in communication between the Transponder and
the Reader. Reason for this can be:
The collision handling algorithm was not continued until no collision is detected, rea-
sons for the break:
- TR-RESPOSE-TIME in CFG1: Interface is to short
- Transponder is in the in the limit reading range
- to much noise in the antenna field
0x84
RF-Warning:
Detailed status information can be read with the command
The antenna configuration isn’t correct. Check the antenna cables and the antenna
matching.
The environment is too noisy.
The RF power doesn’t have the configured value.
0x92
No valid Data:
There is no valid data in the Buffered Read Mode.
There is no Transponder in the antenna field.
The
VALID-TIME
24
hasn’t elapsed for Transponders in the antenna field.
0x93
Data Buffer Overflow:
A data buffer overflow occurred.
0x94
More Data:
There are more Transponder data sets requested than the response protocol can
transfer at once.
0x95
Tag Error
A Tag error code was sent from the transponder. The Tag error code is shown in
the following byte.
Tag Errors for ISO15693 and ISO18000-3M3 Transponder are listed below.