![background image](http://html1.mh-extra.com/html/feig-electronic/id-isc-mr102/id-isc-mr102_manual_3890489036.webp)
Identification
Manual
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 36 of 153
H01113-4e-ID-B.docx
ISO-Blocksize:
Bit:
7
6
5
4
3
2
1
0
Function
Read Mode
Blocksize
DB-Blocksize
DB-Blocksize:
…
(
Transponder.HF.ISO_15693.Miscellaneous.ReadOption.)
Defines the block size of an ISO-transponder which is not listed in the MFR-table
(see: 8.3. Supported ISO15693 Host commands
if the transponder is used in the non-addressed mode.
Range: 0x01 ... 0x1F
A value of 0x00 will be automatically set to a block size of 4byte.
Blocksize:
…
(
Transponder.HF.ISO_15693.Miscellaneous.ReadOption.)
b0:
Automatic (If transponder is known)
b1:
Manuel (As specified in DB-Blocksize)
Read Mode:
…
(
Transponder.HF.ISO_15693.Miscellaneous.ReadOption.ReadMode)
b00:
Automatic Mode (If transponder is known)
b01
Single Read
b10
Multiple Read