![background image](http://html1.mh-extra.com/html/feig-electronic/id-isc-mr102/id-isc-mr102_manual_3890489079.webp)
Identification
Manual
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 79 of 153
H01113-4e-ID-B.docx
Notes:
The
blue LED on ID ISC.SPAD or ID ISC.ANTS370270 need an active H-field and
OUT-S:
OUT-S (Output State) defines the status of the output during the time defined in OUT-
TIME and provides the possibility to allocate its own flashing-frequency to each output.
Bit:
7
6
5
4
3
2
1
0
Function:
0
0
0
0
0
0
OUTx-mode
OUTx-mode:
b00:
OFF
b01:
ON
b10:
FLASHING SLOW
b11:
FLASHING FAST
OUT-TIME:
By the values defined by “OUT-TIME” the outputs can be activated temporary limited or
unlimited.
Accepted are the time values 0 and 65535 (0xFFFF) (see following table).
0x0001
1 x 100ms
-> 100ms
...
...
0xFFFE
65534 x 100ms -> 1:49:13 h
0xFFFF
continuously active
Notes:
In order to reset a continuously active time, OUT-TIME = 1 has to be sent to the
Reader, which effects a change to the idle status after 100 ms.
The continuous activation is being set back after a reset or a power failure.