7.1.3. [0x22] Lock Multiple Blocks
This command locks one or more data blocks.
The supported ISO15693 Host commands depend on the different ISO15693 Transponder types,
they are described in chapter
8.3. Supported ISO15693 Host commands for ISO15693 Transpon-
Note:
This command is only available for ISO15693 Transponders.
REQUEST-DATA
6
7
8
9
1 or 2 Bytes
( def. by
EXT_ADR)
1 Byte
0x22
MODE
UID
BANK
DB-ADR
DB-N
RESPONSE-DATA (STATUS = 0x03)
7
DB-ADR-E
RESPONSE-DATA (STATUS = 0x95)
7
8
ISO15693
ERROR
DB-ADR-E
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0
0
EXT_ADR
0
0
ADR
ADR:
b000
non-addressed
b001
addressed
b010
selected
EXT_ADR:
If this bit is set the command includes extended address fields.
b0:
Transponder memory addressing is done by the 1 byte DB-ADR Field.
b1:
Transponder memory addressing is done by BANK and
2
byte DB-ADR
Field
UID:
Read-only serial number of the Transponder. The UID is required only in the addressed
mode.