![background image](http://html1.mh-extra.com/html/feig-electronic/id-isc-mr102/id-isc-mr102_manual_3890489088.webp)
Identification
Manual
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 88 of 153
H01113-4e-ID-B.docx
BANK:
Memory bank of the Transponder which will be accessed by the Reader
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
0
BANK_NR
BANK_NR:
Defines the memory area on the transponder.
b00
reserved
b01
reserved
b10
reserved
b11
User memory bank
DB-ADR:
First block number to be locked. Depending on EXT_ADR. First block can be any value
between 0 and 255 or 0 and 65535.
DB-N:
Number of data blocks to be locked from the Transponder, starting at DB-ADR.
The maximum number of DB-N, depends on the interface transmit buffer size TX-BUF.
The maximum number of DB-N is:
(TX-BUF - 10 )/(DB-Size+1)
Standard Protocol
(TX-BUF - 12 )/(DB-Size+1)
Advanced Protocol
ISO15693 ERROR:
ISO15693 ERROR code of Transponder response. This byte is only available if STATUS
= 0x95.
DB-ADR-E:
Block number where the error occurred.