![background image](http://html1.mh-extra.com/html/feig-electronic/id-isc-mr102/id-isc-mr102_manual_3890489094.webp)
Identification
Manual
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 94 of 153
H01113-4e-ID-B.docx
DB-N:
Number of data blocks to be written to the Transponder, starting at DB-ADR.
The maximum number of DB-N, depends on DB-Size and the interface receiver buffer
size RX-BUF. The maximum number of DB-N is:
(RX-BUF - 20 )/(DB-Size) e.g. Block size 4 (DB-N = (280
– 20) / 4 = 65)
DB-SIZE:
Number of bytes of one data block.
DB:
Data of the data block to be written to the Transponder. The required block size is defined
by DB-SIZE. The number of the expected bytes are DB-N * DB-SIZE.
TAG ERROR:
TAG ERROR code of Transponder response. This byte is only available if STATUS =
0x95. See:
ANNEX F: Transponder Error Codes
DB-ADR-E:
Block number where the error occurred.
Notes:
If an error occurred during a write command, the number of the block were the error oc-
curred will be send to host
ISO15693:
– A write to 1 block uses a Write Single Block command to the Transponder. This will be
managed by the Reader internally.
– If a Transponder does not support Write Multiple Blocks commands several Write
Single Block commands are used for this Transponder.
I-Code1:
A write command on I-Code1 Transponders can only be performed in the addressed
mode.