H01113-4e-ID-B.docx
6.7. [0x69] RF Reset
The RF-field of the Reader antenna can be switched off for
t
rf
= 15 ms
by the command RF Reset.
Thus, all Transponders which are within the antenna field of the Reader will be reset to their base
setting.
Host
Reader
1
2
3
4
5
6,7
STX
(0x02)
MSB
ALENGTH
LSB
ALENGTH
COM-ADR
[0x69]
CRC16
Host
Reader
1
2
3
4
5
6
7,8
STX
(0x02)
MSB
ALENGTH
LSB
ALENGTH
COM-ADR
[0x69]
STATUS
16
CRC16
Notes:
After a RF Reset the Reader is not able to receive a new Transponder before expiration of
t
rf
.
After a RF Reset, a Transponder which is located within the field has to be re-selected.
The response of this command will be sent after the RF Reset was completed.
6.8.
[0x6A] RF ON/OFF
The command RF ON/OFF switches the RF field of the Reader antenna ON and OFF.
Host
Reader
1
2
3
4
5
6
7,8
STX
(0x02)
MSB
ALENGTH
LSB
ALENGTH
COM-ADR
[0x6A]
RF
CRC16
Host
Reader
1
2
3
4
5
6
7,8
STX
(0x02)
MSB
ALENGTH
LSB
ALENGTH
COM-ADR
[0x6A]
STATUS
17
CRC16
RF:
0x00
RF-Field of Reader antenna is OFF
0x01
RF-Field of Reader antenna is ON
16
see ANNEX E: Index of Status Bytes