OBID
i-scan
®
UHF
Manual
ID ISC.MU02.02
FEIG ELECTRONIC GmbH
Page 92 of 96
H90701-3e-ID-B
0x15
Read Protect:
•
The configuration block is reserved for future use.
0x16
Write Protect:
•
The configuration block is reserved for future use.
0x17
Firmware activation required:
The firmware must be activated first using ISOStart demo program and the command “Set Firmware
Upgrade”. The update code must be ordered by Feig Electronic.
1. Read the Device-ID using the command [0x66] Firmware version (Mode 0x80)
2. Send the Device-ID and the serial number of the reader to Feig Electronic
3. Write the upgrade code into the reader using the command [0x5F] Set Firmware Update
0x80
Unknown Command:
•
The Reader does not support the selected function.
0x81
Length-Error:
•
The selected function has the wrong number of parameters.
0x82
Command not available:
•
A Host command was sent to the Reader in the Scan Read Mode.
•
A Scan Mode protocol was sent to the Reader in the standard mode
•
The command with More bit does not correspond with the last command
0x83
RF communication error:
This error indicates that there is an error in communication between the Transponder and the Reader.
Reason for this can be:
•
Timeout for Transponder communication. “Transponder-Response-Time” in
•
The collision handling algorithm was not continued until no collision is detected, reasons for the
break:
0x84
RF-Warning:
Detailed status information can be read with the command
•
The antenna configuration isn’t correct. Check the antenna cables and the antenna matching.
•
The environment is too noisy.
•
The RF power doesn’t have the configured value.
0x94
More Data:
•
There are more Transponder data sets requested than the response protocol can transfer at once.
0x95
Tag Error
•
A Tag error code was sent from the transponder. The Tag error code is shown in the following byte.
0xF1
Hardware Warning:
•
RF-Decoder works not properly
•
Communication link between RF-Decoder and RFC works not properly