IDENTIFICATION
ID LR(M)5400
Installation and mounting
Installation
Page 22 of 30
Bild 2: Jumper RS485-Peripherie-Device Interface
2.9.1.1 Address assignment of RS485 for bus operation
For bus operation the Reader can be assigned the required bus address via software.
The address is assigned by the host computer. The software is used to assign addresses “0” through “254”
to the Reader.
The termination of the RS485 Bus can be configured via software.
NOTE
Since all Readers are factory set with address „0“, they must be connected and configured one after the other.
2.9.2 USB Interface X4 (Host Communication, HID)
•
USB socket on terminal X4
Use standard USB cable, length
≤ 5 m
•
Data-rate:
≤ 12 Mbit (USB Full Speed)
•
Connection to external host
Figure 22: : USB-Interface for host communication