background image

IDENTIFICATION 

 

9    Transmitting Data to a Host 

 

 

 

Page 15 of 15 

 

Pos : 38 /ID P/M anuals/Ü bersc hrift en/1/Trans mitti ng Barc ode and/ or RF ID D at a t o a H ost  @ 3\ mod_1542021992638_10021.doc x @ 56007 @ 1 @ 1 

 
9  Transmitting Barcode and/or RFID Data to a Host 

Transmitting Data to a Host 

Pos : 39 /ID P/M anuals/PANMO BI L/Tr ans mitti ng Barcode and/ or RFID  Dat a to a Hos t @ 3\ mod_1542022060134_10021. doc x @  56017  @   @  1 

 

Batch mode 

All barcodes and RFID data scanned in batch mode are saved in the file “Output.txt” on the removable drive 
“SCANNDY”. Connect the device to the host computer via USB and use the Windows-Explorer to navigate to 
the device “SCANNDY”. Copy the file “Output.txt” to the host. 

To delete the data from the device just delete the file “Output.txt”. 

Transmitting data from a Bluetooth or Wi-Fi device 

When the scanner is paired to a host via Bluetooth, the data transmits to the host after each scanning 
procedure and is not stored on the scanner unless the scanner moves out of the range of the host. For out of 
range usage you can configure the device to either store the data in a cache memory or do not allow 
scanning. 

If the device was configured to store the out of range captured data, it stores the data in a file Cache.txt. 
After reconnection, it transmits all cached data to the host. 

Bidirectional communication for Bluetooth and Wi-Fi connected devices 

For applications that require bidirectional communication between the device and the host, PANMOBIL 
devices support an embedded communication protocol SCOMP and REMOTE mode. 
 

 

Summary of Contents for ID PM ECCO+

Page 1: ...1 18 T V NORD Hochfrequenztechnik GmbH Co KG Rottland 5a 51429 Bergisch Gladbach Germany Tel 49 2207 9689 0 Fax 49 2207 9689 20 Annex acc to FCC Title 47 CFR Part 15 relating to FEIG Electronic GmbH I...

Page 2: ...IDENTIFICATION os 2 ID P D eckblatt_M anual 0 mod_1526622727845_10021 docx 13771 1 Ende der Liste f r Textmar ke Deckbl att MANUAL ID PM ECCO Compact and Robust RFID Barcode Scanner...

Page 3: ...ot be completely avoided we are always grateful for your useful tips The instructions given in this manual are based on advantageous boundary conditions FEIG ELECTRONIC GmbH does not give any guarante...

Page 4: ...2 1D 2D Imager 10 6 Scanning RFID 11 7 Bluetooth Connection 12 7 1 Numeric Barcodes for Bluetooth Pairing 13 8 Wi Fi Connection 14 9 Transmitting Barcode and or RFID Data to a Host 15 10 Technical sp...

Page 5: ...Use of Wireless Devices 20 13 8 Potentially Hazaedous Atmospheres Vehicle Use 21 13 9 Safety in Aircrafts 21 13 10 Safety in Hospitals 21 13 11 Pacemakers 21 13 12 Other Medical Devices 21 13 13 RF E...

Page 6: ...er function can be user defined with the programming interface 2 Yellow LED Lights up yellow if a barcode or RFID tag was read successfully Is flashing yellow 500ms when connected to USB Further funct...

Page 7: ...turns the unit OFF 9 USB protection clip Mini USB interface Rubber clip to protect the Mini USB port Main communication and battery charging interface 10 Scanning window RFID antenna option Protectio...

Page 8: ...be lost by the reset Pos 13 ID P M anuals berschriften 1 Configur ati on Mode 3 mod_1542016638737_10021 docx 55639 1 1 3 Configuration Mode Configuration Mode Pos 14 ID P M anuals PANMOBIL C onfigura...

Page 9: ...ry is charging the red LED 3 will light solid red After the battery is fully charged the red LED 3 turns off A full recharge of the battery takes approx 4 to 5 hours when using the included power adap...

Page 10: ...2017806783_10021 docx 55697 2 1 5 1 1D Laser Pos 21 ID P M anuals PANMOBIL Scanning Barcode 1D Laser 3 mod_1542018707813_10021 docx 55916 1 To scan a barcode follow the steps below 1 Aim the scanner o...

Page 11: ...5916 1 To scan a barcode follow the steps below 1 Aim the scanner on the barcode 2 Press the trigger key 5 3 The ID PM ECCO decodes the barcode closest to the cross center unless you disable the Pick...

Page 12: ...NMOBIL Scanning RFID 3 mod_1542020944563_10021 docx 55962 1 To scan an RFID tag follow the steps below 1 Aim the scanner on the RFID tag 2 Make sure the tag is within the reader range 3 Press the trig...

Page 13: ...h Keyboard Emulation HID The scanner connects to the host via Bluetooth and emulates a keyboard The scanner accepts an incoming connection requested by a Bluetooth host 2 Save the settings and disconn...

Page 14: ...c Barcods for Bluetooth Pairing 3 mod_1542017912662_10021 docx 55737 2 1 7 1 Numeric Barcodes for Bluetooth Pairing Pos 33 ID P M anuals PANMOBIL N umeric Barcodes for Bluetooth Pairing 3 mod_15420217...

Page 15: ...e parameters for Wi Fi and host connection See the document Config_ini section Wi Fi to learn how to set the parameters for Wi Fi communication 3 Save the settings and disconnect the device from the c...

Page 16: ...host To delete the data from the device just delete the file Output txt Transmitting data from a Bluetooth or Wi Fi device When the scanner is paired to a host via Bluetooth the data transmits to the...

Page 17: ...ss storage USB HID USB Ethernet USB Serial 2 4 GHz IEEE 802 11 b g n Bluetooth Class 2 HiD SPP Battery 1250 mAh Lithium Ion 3 7 V Indicators LED red green yellow blue Speaker Vibration feedback Keyboa...

Page 18: ...t the device is in the correct Bluetooth Mode HID or SPP Ensure that you are paired correct to your host Renew your pairing with your host system Wi Fi is not working Ensured that the device is in the...

Page 19: ...cial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio co...

Page 20: ...barcode scanner is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC European countries where this equipment can be used are Austria AT Belgium BE Bul...

Page 21: ...ironment Pos 55 ID P M anuals berschriften 2 Vehicle Install ati on 3 mod_1542018124697_10021 docx 55807 2 1 13 5 Vehicle Installation Pos 56 ID P M anuals PANMOBIL Appr ovals Vehicle Install ati on 3...

Page 22: ...ical equipment Wireless devices should be switched off wherever you are requested to do so in hospitals or healthcare facilities to prevent interference with sensitive medical equipment Pos 67 ID P M...

Page 23: ...hose already approved in this filling Handheld Devices To comply with FCC RF exposure requirements the device must be operated in the hand with a minimum separation distance of 20cm from a person s bo...

Page 24: ...CFR Part 15 Date of issue 2019 02 26 Date 2018 06 06 Created P4 Reviewed P9 Released P1 Vers No 1 18 T V NORD Hochfrequenztechnik GmbH Co KG Rottland 5a 51429 Bergisch Gladbach Germany Tel 49 2207 968...