background image

OBID

®

Installation

ID RW02.10-AD/-B

Page 18 of 31

FEIG ELECTRONIC GmbH

E N G L I S H

Note

©

 Copyright 2008 by

FEIG ELECTRONIC GmbH
Lange Strasse 4
D-35781 Weilburg-Waldhausen
Tel.: +49 6471 3109-0

http://www.feig.de

With the edition of this document, all previous editions become void. Indications made in this document may

be changed without previous notice.

Copying of this document, and giving it to others and the use or communication of the contents thereof are

forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved

in the event of the grant of a patent or the registration of a utility model or design.

Composition of the information in this document has been done to the best of our knowledge. FEIG

ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this

manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since,

despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.

The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC

GmbH does not give any guarantee promise for perfect function in cross environments and does not give

any guaranty for the functionality of the complete system which incorporates the subject of this document.

FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed

with components and testing methods for a level of reliability suitable for use in or in connection with surgical

implants or as critical components in any life support systems whose failure to perform can reasonably be

expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application

designer must take reasonably prudent steps to protect against system failures.

FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this docu-

ment and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does

not convey any license under its patent rights nor the rights of others. 

OBID

® 

is a registered trademark of FEIG ELECTRONIC GmbH.

All cited brand names, product names, or trademarks belong to their respective holders.

Summary of Contents for multijob-Reader OBID ID RWA02.10-A

Page 1: ...MONTAGE INSTALLATION final public B 2008 09 26 M80806 1de ID B doc OBID ID RWA02 10 A ID RWA02 10 B multijob Reader deutsch english...

Page 2: ...OBID Montage ID RWA02 10 A B Seite 2 von 31 FEIG ELECTRONIC GmbH D E U T S C H deutsche Version ab Seite 3 english version from page 18 E N G L I S H...

Page 3: ...keine Gew hrleistung f r die Richtigkeit und Vollst ndigkeit der An gaben in diesem Dokument Insbesondere kann FEIG ELECTRONIC GmbH nicht f r Folgesch den auf Grund fehlerhafter oder unvollst ndiger...

Page 4: ...rgung 9 4 3 Relais 10 4 4 Digitale Eing nge 10 4 5 RS232 Schnittstelle ID RWA02 10 A 10 4 6 RS485 Schnittstelle ID RWA02 10 B 11 4 7 Adresseinstellung Busbetrieb mit RS485 Schnittstelle 12 5 Inbetrieb...

Page 5: ...rt werden Anschluss Inbetriebnahme Wartungs und sonstige Arbeiten am Ger t d rfen nur von Elektrofachkr ften mit einschl giger Ausbildung erfolgen Alle Arbeiten am Ger t und dessen Aufstellung m ssen...

Page 6: ...chen montiert werden da diese Fl chen eine Reduzie rung der Lesereichweite bewirken Bei der Montage auf Metalloberfl che sollte die Montage mit dem Aufputzadapter erfol gen damit ein ausreichender Ab...

Page 7: ...der Wand verschrauben Montagerichtung TOP beachten siehe Kapitel 3 Montage Geh useoberteil gerade auf das Geh useunterteil aufstecken und einrasten Stiftleiste X1 der Leserelektronik sauber in Buchse...

Page 8: ...WG26 bis AWG18 Empfohlener Au endurchmesser der Anschlussleitung bei Aufputzmontage 7 0 mm Empfohlene Aufbau paarverseilt TP Abbildung 6 Anschlussplatine Klemme Funktion Leiste Bezeichnung ID RWA02 10...

Page 9: ...V AC oder DC versorgt werden Die Polarit t bei DC Spannungsversorgung kann frei gew hlt werden Bei der Dimensionierung des Netzteils und der Anschlussleitung ist der Spannungsabfall auf der Versorgun...

Page 10: ...er die Klemmen NO und COM 4 4 Digitale Eing nge Die beiden digitalen Eing nge IN1 bzw IN2 d rfen nur gegen intern GND Klemme GND ge schaltet werden siehe Abbildung 8 Eine Beschaltung mit Fremdspannung...

Page 11: ...en Leitrechner mit Abschlusswiderstand und aktiver Terminierung voraus Als Leitung wird eine paarweise verseilte oder verdrillte Leitung empfohlen Host ohne Abschlu widerstand R A T B ID RW02 mit akti...

Page 12: ...en Adresse versehen Adresse DIP 1 DIP 2 DIP 3 DIP 4 0 OFF OFF OFF OFF 1 ON OFF OFF OFF 2 OFF ON OFF OFF 3 ON ON OFF OFF 4 OFF OFF ON OFF 5 ON OFF ON OFF 6 OFF ON ON OFF 7 ON ON ON OFF 8 OFF OFF OFF ON...

Page 13: ...on dem multijob Reader eingelesen werden 5 2 LED und Beeper Anzeigen Mode Anzeige Beschreibung je 200 ms rot aus gr n aus multijob Reader wartet auf OBID MasterCard 1 x 800 ms gr n Beeper OK OBID Mast...

Page 14: ...ive Luftfeuchte 95 nicht betauend MTBF 307000 h Antenne intern Betriebsfrequenz 125 kHz unterst tzte Transpondertypen ID CTx A z B H4001 4002 ID DTx B HITAG1 und HITAG S ID DTx C HITAG 2 LED Bicolor r...

Page 15: ...schl gigen Bestimmungen der R TTE Richtlinie 1999 5 EG vom M rz 99 Equipment Classification gem ETSI EN 300 330 und ETSI EN 301 489 Class 2 6 1 2 USA FCC FCC ID PJMRW02 This device complies with Part...

Page 16: ...H 6 2 Abmessungen 60 0 mm 60 0 mm 84 2 mm 84 2 mm 77 7 mm 56 8 mm 60 0 mm 28 4 mm 28 4 mm 77 7 mm Abbildung 13 Unterputzgeh use Befestigungsmasse Abbildung 14 Aufputzadapter Befestigungsmasse 84 2 mm...

Page 17: ...OBID Montage ID RWA02 10 A B FEIG ELECTRONIC GmbH Seite 17 von 31 D E U T S C H...

Page 18: ...seful tips The instructions given in this manual are based on advantageous boundary conditions FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and d...

Page 19: ...Jumper and Switches 24 4 2 Power supply 24 4 3 Relay 25 4 4 Digital inputs IN1 IN2 25 4 5 RS232 Interface ID RWA02 10 A 25 4 6 RS485 Interface ID RWA02 10 B 26 4 7 Address setting Bus mode with RS485...

Page 20: ...ice Repairs may only be executed by the manufacturer Installation operation and maintenance procedures should only be carried out by qualified personnel Use of the device and its installation must be...

Page 21: ...al grids reinforcements or metallized surfaces as these surfaces reduce the detection range of the Reader If an installation to a metal surface becomes necessary the surface adapter can be em ployed i...

Page 22: ...t of casing to selected surface Take care about the mounting direction TOP see chapter 3 Installation Put the casing upper part straight onto its bottom part and snap it in see Fig 4 Insert the pin bo...

Page 23: ...e which is snapped into the bottom part of the casing connector function board name ID RW02 ABC A ID RW02 ABC B power supply 12 24 AC DC CLS COM NO relay GND internal GND R A RS232 RxD RS485 A X2 T B...

Page 24: ...The device may be supplied ei ther with 12 24 V AC or DC In case of DC supply the polarity may be chosen freely For the dimensioning of the power supply and the connecting cable the voltage drop on t...

Page 25: ...and COM 4 4 Digital inputs IN1 IN2 The digital inputs IN1 and IN2 can only be connected to internal GND terminal GND accord ing to Fig 8 connection of the digital inputs Any connection to external vol...

Page 26: ...d Fig 6 To operate the bus you need a host computer with a terminating resistor and active termination A twisted paired or stranded wire is recommended Host without termination R A T B ID RW02 with ac...

Page 27: ...ing provided with an individual address Address DIP 1 DIP 2 DIP 3 DIP 4 0 OFF OFF OFF OFF 1 ON OFF OFF OFF 2 OFF ON OFF OFF 3 ON ON OFF OFF 4 OFF OFF ON OFF 5 ON OFF ON OFF 6 OFF ON ON OFF 7 ON ON ON...

Page 28: ...y be read by the multijob Reader 5 2 LED and beeper signals Mode Signal Description 200 ms at a time red off green off multijob Reader waiting for OBID MasterCard 1 x 800 ms green beeper OK OBID Maste...

Page 29: ...e air humidity 95 non condensing MTBF 307000 h Antenna integrated Operating Frequency 125 kHz Supported Transponder types ID CTx A e g H4001 4002 ID DTx B HITAG1 and HITAG S ID DTx C HITAG 2 LED bicol...

Page 30: ...vant provisions of the R TTE Directive 1999 5 EG of March 99 Equipment Classification according to ETSI EN 300 330 and ETSI EN 301 489 Class 2 6 1 2USA FCC FCC ID PJMRW02 This device complies with Par...

Page 31: ...31 E N G L I S H 6 2 Dimensions 60 0 mm 60 0 mm 84 2 mm 84 2 mm 77 7 mm 56 8 mm 60 0 mm 28 4 mm 28 4 mm 77 7 mm Fig 13 Concealed casing Fixing dimensions Fig 14 Surface adapter dimensions 84 2 mm 84 2...

Reviews: