OBID
®
Installation
ID RW02.10-AD/-B
FEIG ELECTRONIC GmbH
Page 21 of 31
E N G L I S H
3. Installation
The Reader has been designed for wall installation on 60 mm flush-mounting box. For surface in-
stallation you can use the surface adapter.
NOTES:
•
The Reader must not be installed directly upon conductive materials as e.g. metal sur-
faces, metal grids (reinforcements) or metallized surfaces, as these surfaces reduce the
detection range of the Reader.
If an installation to a metal surface becomes necessary, the surface adapter can be em-
ployed in order to keep the minimal distance.
•
The distance between two Readers of the same type should not fall below 30 cm.
•
Before any installation the intended position of the Reader should be tested for its suit-
ability.
Fig. 1 Surface adapter,
Mounting direction,
(
⇑
TOP) on top position
Fig. 2 Concealed casing,
Mounting direction,
(
⇑
TOP) on top position