OBID
®
classic-pro
Manual
ID CPR30.xx
FEIG ELECTRONIC GmbH
Page 114 of 126
H01114-0e-ID-B.docx
8.3.7. NXP (I-Code SLI)
IC manufacturer identifier: 0x04
Memory organization: 32 x 4 Byte = 1kBit
Number of blocks 32 (user area: 0 – 27)
Block size
4 byte
Command
Code
Function
Mode
Comment
non-
addressed
addressed
select
0x01
Inventory
-
-
-
0x02
Stay Quiet
-
-
0x22
Lock Multiple Blocks
WR-OPTION = 0
*
0x23
Read Multiple Blocks
DB-Size = 4
Security Status is always
0x00
0x24
Write Multiple Blocks
DB-Size = 4,
WR-OPTION = 0
*
0x25
Select
-
-
0x26
Reset to Ready
0x27
Write AFI
WR-OPTION = 0
*
0x28
Lock AFI
WR-OPTION = 0
*
0x29
Write DSFID
WR-OPTION = 0
*
0x2A
Lock DSFID
WR-OPTION = 0
*
0x2B
Get System Information
0x2C
Get Multiple Block Security
Status
The WR-OPTION will be set automatically by the FEIG Readers if the RW-OPTION parameter in
“CFG8 General” is set to “00: automatically set” (3.5. CFG4: Transponder Parameters).