ANNEX C: Index of Status Bytes
Hex-value
General
0x00
OK:
Data / parameters have been read or stored without error
Control command has been executed
Hex-value
Transponder Status
0x01
No Transponder:
No Transponder is located within the detection range of the Reader.
The Transponder in the detection range has been switched to mute.
The communication between Reader and Transponder has been interfered and the Reader is not
able to read the Transponder anymore.
0x02
Data False:
CRC, parity or framing error at received data.
0x03
Write-Error:
Negative plausibility check of the written data:
Attempt to write on a read-only storing-area.
Too much distance between Transponder and Reader antenna.
Attempt to write in a noise area.
0x04
Address-Error:
The required data are outside of the logical or physical Transponder-address area:
The address is beyond the max. address space of the Transponder.
The address is beyond the configured address space of the Transponder.
0x05
Wrong Transponder-Type:
This command is not applicable at the Transponder:
Attempt to write on or read from a Transponder.
A special command is not applicable to the Transponder.
0x08
Authent-Error
The reader could not identify itself to the transponder as authorized:
reader- and transponder Keys do not correspond
0x0E
General-Error
The Transponder answered with an undefined or general error code
0x83
RF Communication Error:
Anticollision could not be finished by the reader.
Corrupted or faulty data exchange between reader and Transponder
0x92
No valid Data:
There is no valid data in the buffer.
There is no Transponder in the antenna field.
0x93
Data Buffer Overflow:
A data buffer overflow occurred.
0x94
More Data:
There are more Transponder data sets requested than the response protocol can transfer at once.
0x95
ISO15693-Error:
An additional error code for ISO15693 Transponders is sent with response data.
0x96
ISO14443-Error:
An additional error code for ISO14443 Transponders is sent with response data. (see: ANNEX C2:
Hex-value
Parameter Status
0x10
EEPROM-failure:
The EEPROM of the Reader is not able to be written on.
Before writing onto the EEPROM a faulty checksum of parameters has been detected.
0x11
Parameter-Range-Error:
The value range of the parameters was exceeded.