3.2. CFG1: Interface
The parameters of the CFG1 configuration block contain the data communication settings.
Byte
0
1
2
3
4
5
6
Contents
COM-ADR
0x00
BAUD
TRANS-
FORM
0x00
0x00
TR-
RESPONSE-
TIME
Default
0x00
0x00
0x08
0x01
0x00
0x00
0x00
Byte
7
8
9
10
11
12
13
Contents
TR-
RESPONSE-
TIME
0x00
0x00
0x00
0x00
0x00
READER -
MODE
Default
0x16
0x00
0x00
0x00
0x00
0x00
0x00
2,2 sec.
COM-ADR:
Bus address of the Reader (0 .. 254) for communication via the asynchronous interface.
Notes:
Do not configure address 255!
Via the COM-ADR 255 in the send protocol, the Reader is able to be addressed at
any time. It answers then with the configured address.
BAUD
1
:
By means of this byte the baud rate of the asynchronous interface can be defined.
BAUD
ID CPR30.xx
0x05
4.800
bit/s
0x06
9.600
bit/s
0x07
19.200
bit/s
0x08
38.400
bit/s
0x09
57.600
bit/s
0x0B
115.200
bit/s
0x0D
230.400
bit/s
0x80
-
bit/s
0x81
-
bit/s
0x82
-
bit/s
0x83
-
bit/s
NOTICE:
1
A plausibility check is performed by writing this parameter to the Reader. If an error occurs the Reader an-
swers with STATUS = 0x11.