OBID
®
classic-pro
Manual
ID CPR30.xx
FEIG ELECTRONIC GmbH
Page 25 of 126
H01114-0e-ID-B.docx
3.4. CFG3: RF-Interface
The parameters of the CFG3 configuration block contain global Transponder driver and Reader set-
tings.
Byte
0
1
2
3
4
5
6
Contents
TAG-DRV
ISO14443-DRV
0x00
0x00
0x00
Default
0x0038
0x000E
0x00
0x00
0x00
Byte
7
8
9
10
11
12
13
Contents
ISO14443
BIT RATE
0x00
0x00
0x00
0x00
ISO14443
STUPT
ISO14443
FTUR
Default
0x00
0x00
0x00
0x00
0x00
0x03
15 ms
0x1A
TAG-DRV
1
:
Defines the Transponder types that are operated by the Reader.
Byte:
0
1
Bit:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Driver
0
0
0
0
0
0
0
0
0
0
F
E
D
0
0
0
Default
0
0
0
0
0
0
0
0
0
0
1
1
1
0
0
0
b0:
Driver for the Transponder type is disabled
b1:
Driver for the Transponder type is activated
.D:
Driver for ISO15693
.E:
Driver for ISO14443A
.F:
Driver for ISO14443B
Only those Transponder drivers should be active that are used in the current appli-
cation. Thus, the reaction time of the Reader for Transponder read- / write-
operations is reduced and the danger of a parasitic Transponder access is mini-
mized.
1
A plausibility check is performed by writing this parameter to the Reader. If an error occurs the Reader an-
swers with STATUS = 0x11.