4.3. [0x83] Set Default Configuration (Configuration RESET)
Using the command Set Default Configuration each configuration block can be reset to the manu-
facturer's setting.
Host Reader
1
2
3
4
5
6
7...8
STX
(0x02)
MSB
ALENGTH
LSB
ALENGTH
COM-ADR
[0x83]
CFG-ADR
CRC16
Host Reader
1
2
3
4
5
6
7...8
STX
(0x02)
MSB
ALENGTH
LSB
ALENGTH
COM-ADR
[0x83]
STATUS
CRC16
CFG-ADR:
Bit:
7
6
5
4
3
2
1
0
Function
LOC
MODE
CFGn
CFGn:
Memory-address of the required configuration block.
MODE:
Specifies one or all configuration blocks.
b0:
configuration block specified by CFGn
b1:
all configuration blocks
LOC:
Specifies the location of the configuration block.
b0:
RAM
b1:
EEPROM
Notes:
To store RAM configuration over power down use
Fehler! Verweisquelle konnte nicht ge-
funden werden.
A set default configuration with reserved configuration blocks will cause an error code.