OBID
®
classic-pro
Manual
ID CPR30.xx
FEIG ELECTRONIC GmbH
Page 48 of 126
H01114-0e-ID-B.docx
OUT-S:
OUT-S (Output State) defines the status of the output during the time defined in OUT-TIME
and provides the possibility to allocate its own flashing-frequency to each output.
Bit:
7
6
5
4
3
2
1
0
Function:
0
0
0
0
0
0
OUTx-mode
OUTx-mode:
b00:
OFF
b01:
ON
b10:
FLASHING SLOW
OUT-TIME:
By the values defined by “OUT-TIME” the outputs can be activated temporary limited or un-
limited.
Accepted are the time values 0 and 65535 (0xFFFF) (see following table).
0x0001
1 x 100ms
-> 100ms
...
...
0xFFFE
65534 x 100ms -> 1:49:13 h
0xFFFF
continuously active
Notes:
In order to reset a continuously active time, OUT-TIME = 1 has to be sent to the
Reader, which effects a change to the idle status after 100 ms.
The continuous activation is being set back after a reset or a power failure.
5.8.1. Set Output Examples
Example No. 1:
LED1 is alternating fast for 500 ms.
LED2 is not activated for 200 ms.
BUZZER is activated for 1000ms
LED3 and RELAY are unchanged
OUT-N
OUT-NR
OUT-S
OUT-TIME
0x0003
0x21
0x03
0x0005
OUT-NR
OUT-S
OUT-TIME
0x22
0x00
0x0002
OUT-NR
OUT-S
OUT-TIME
0x41
0x01
0x000A