6.1.9. [0x24] Write Multiple Blocks (extended Address Mode)
This command writes one or more data blocks.
The supported ISO15693Host commands depend on the different ISO15693Transponder types,
which are described in chapter
Fehler! Verweisquelle konnte nicht gefunden werden.
.
REQUEST-DATA
6
7
8
9
1 or 2 Bytes
( def. by
EXT_ADR)
1 Byte
1 Byte
DB-N times DB-
SIZE Bytes
0x24
MODE
UID
BANK
DB-ADR
DB-N
DB-SIZE
DB
Repeated DB-N
times
RESPONSE-DATA (STATUS = 0x03)
7
DB-ADR-E
RESPONSE-DATA (STATUS = 0x95)
7
8
ISO15693
ERROR
DB-ADR-E
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0
0
EXT_ADR
0
0
ADR
ADR:
b000
non-addressed
b001
addressed
b010
selected
EXT_ADR:
If this bit is set the command includes extended address fields.
b0:
Transponder memory addressing is done by the 1 byte DB-ADR Field.
b1:
Transponder memory addressing is done by BANK and
2
byte DB-ADR
Field
UID:
Read-only serial number of the Transponder. The UID is required only in the addressed
mode.