OBID
®
classic-pro
Manual
ID CPR30.xx
FEIG ELECTRONIC GmbH
Page 76 of 126
H01114-0e-ID-B.docx
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
FIRST
MORE
-
-
PING
NAD_E
CID_E
INF
MODE bit setting rules
MODE
DATA
6
7
8...n-2
b1000 0001
(INF)
APDU without CID or NAD (single block)
b1100 0001
(INF)
APDU without CID or NAD (first chained block)
b0100 0001
(INF)
APDU without CID or NAD (further chained block)
b0000 0001
(INF)
APDU without CID or NAD (last chained block)
b1000 0011
CID
(INF)
APDU with CID (single block)
b1100 0011
CID
(INF)
APDU with CID (first chained block)
b1000 0101
NAD
(INF)
APDU with NAD (single block)
b1100 0101
NAD
(INF)
APDU with NAD (first chained block)
b1000 0111
CID
NAD
(INF)
APDU with CID and NAD (single block)
b1100 0111
CID
NAD
(INF)
APDU with CID and NAD (first chained block)
b1000 0000
-
DESLECT without CID or NAD
b1000 0010
CID
-
DESLECT with CID
b1000 100x
-
PING without CID or NAD
b1000 101x
CID
-
PING with CID
INF:
b0
"DESELECT"
Sends the S-block command "DESELECT" to the present Transponder.
b1
"APDU"
Instructs the Reader to send the INF Block (APDU) which is included in
the DATA Block to the Transponder.
CID_E:
b0
The DATA Block includes no CID
b1:
The DATA Block includes an optional 1 byte CID Parameter
The CID has to be placed in DATA directly behind the MODE Parameter
NOTICE:
In case of command chaining (see Bit "MORE") only the CID in the first
command block is accepted by the Reader.