STATUS = ERROR (STATUS not 0x00 or 0x94)
This response is given by the Reader if the present command could not be fi-
nished, because of transmission errors.
6
7
STATUS
(ISO14443-
ERROR)
STATUS:
see ANNEX C: Index of Status Bytes.
ISO14443-ERROR
Additional error code if STATUS = 0x96 (see ANNEX C2: ISO14443-
Error, Error-Codes)
BLK_CNT:
The BLK_CNT is a block counter which indexes each transmission from the Reader to the
Host. On basis of the BLK_CNT the host could proof and sort the received protocols.