OBID
®
classic-pro
Manual
ID CPR30.xx
FEIG ELECTRONIC GmbH
Page 88 of 126
H01114-0e-ID-B.docx
TX-SETTINGS:
Selects kind and mode of transmission settings.
Bit:
7
6
5
4
3
2
1
0
Function
-
-
-
-
-
-
BAUDRATE
BAUDRATE
b00:
106 kBaud
b01:
212 kBaud
b10:
424 kBaud
b11:
848 kBaud
RX-SETTINGS:
Selects kind and mode of reception settings.
Bit:
7
6
5
4
3
2
1
0
Function
-
-
-
-
-
-
BAUDRATE
BAUDRATE
b00:
106 kBaud
b01:
212 kBaud
b10:
424 kBaud
b11:
848 kBaud
REQ-BITS:
Number of valid Bits in REQUEST-DATA
REQUEST-DATA:
Complete transponder request without SOF and EOF. If “
TxCRCEn”
is “1” the reader ap-
pended a calculated CRC to the date stream. If “
TxCRCEn”
is “0” the application should
send the CRC within the
Request-Data
, if the CRC is needed.
RESPONSE-DATA
:
Complete transponder response without SOF and EOF. A CRC check is performed inside
the reader if “
RxCRCEn”
is “1”. However if “
RxCRCEn”
is “0”the transponder CRC is
transferred with the response data.
RSP-BITS:
Number of valid Bits in RESPONSE-DATA
NOTICE:
Data is only transferred if STATUS = 0x00, 0x02, 0x83, 0x84, 0x94.