If RSP-LENGTH is set to “0” the Reader will send the command but not wait for any re-
sponse. If RSP-LENGTH is not equal to “0” the Reader will send the command and return
the response data of the Transponder without SOF and EOF.
TIMEOUT:
The TIMEOUT value defines the time for receiving the whole Transponder response. If the
TIMEOUT it exceeded the command will be abort and the Status “NO TRANSPONDER” is
returned.
Bit:
7
6
5
4
3
2
1
0
Function
FWI-
VALUE
Timeout-Value
FWI-VALUE:
b0:
The Timeout-Value can be adjusted in 1ms steps. (0ms ...127ms)
b1:
The Timeout Value is equivalent to the FWI value according to
ISO14443-4. (0...14)
With this parameter the Frame waiting time (FWT) according ISO14443-4
could be select by the user
TIMEOUT
(FWI)
approx. Frame waiting time
(FWT)
0
1 ms
1
1 ms
2
2 ms
3
3 ms
4
5 ms
5
10 ms
6
20 ms
7
39 ms
8
78 ms
9
155 ms
10
310 ms
11
619 ms
12
1237 ms
13
2474 ms
14
4948 ms
15..254
- not allowed -
NOTICE:
The value of TIMEOUT must be considered for calculating the HOST-TIMEOUT.
The value of TIMEOUT must be considered for calculating the TR-RESPONSE-TIME (see
CFG1).