OBID i-
scan
®
Installation
ID ISC.ANT1700/740-A /-B
FEIG ELECTRONIC GmbH
Page 41 of 74
M91201-5e-ID-B.doc
5.5 Setting the Alarm indicators (Alarm sounder and Alarm LED lights)
The solution provided here presumes that the Alarm Sounder is switched through the digital output
2 (X2 Pin OUT2-C,OUT2-E), Alarm LED 1 of antenna No.1 through relay No.1 (X2, Pin REL1-
COM) , Alarm LED 2 of antenna No.2 through relay No.2 (X2, Pin REL2-COM) and Alarm LED 3 of
antenna No.3 through relay No.3 (X2, Pin REL3-COM) on the ID ISC.LRM2500-B reader. The
pulse duration can be set (Digital IO / OUTPUT or RELAY) between 100 ms and 6553.5 s by
adjusting the Reader configuration. The volume of the sounder could be adjusted by a
potentiometer on the terminal board.
Fig. 23 Volume adjusting
To supply the Alarm LED lights with 24V DC the following jumper on the LRM2500 has to be set.
JP7,8 and 9.
Fig. 24 Jumper settings for relay