OBID i-
scan
®
Installation
ID ISC.ANT1700/740-A /-B
FEIG ELECTRONIC GmbH
Page 44 of 74
M91201-5e-ID-B.doc
If a Gate People Counter GPC is installed, the Alarm LED lights LED 1 to 3 will be switched by the
digital outputs 1 to 3 of the GPC. See page:
Installation of the Gate People Counter ID
5.5.2 Programming a Transponder with the AFI Byte
If the Transponders will remain on the object when leaving the storage location, they must first be
cancelled. This is generally done by writing to a particular area of the Transponder.
The AFI byte (Application Family Identifier) is useful for this purpose, since it is contained in nearly
all Transponder models in the ISO15693 family. To cancel, simply write a different code to the
Transponder than for valid Transponders which trigger an alarm.
Step
Action:
Note:
1
Select „Commands“
2
Place the Transponder in the
antenna field (Antenna 1)
Select [0x01] Inventory
Mode: New Inventory
Requested
3
Read UID by clicking on
„Send“
4
The serial number, DSFID
and Transponder type are
displayed in a window.
Write down the serial number
of the Transponder
5
Select „[0x27] Write AFI“
ADR:
1: addressed
Serial Number:
Select TransponderUID
AFI:
Desired AFI Number (not
equal to 00)
6
Write AFI byte on to the
transponder by click on
„Send“