M91201-5e-ID-B.doc
The Reader needs to be configured as follows depending on the installation location:
Parameter
USA / Canada / Europe
Air Interface
RF-Power:
maximum 8 W
RF Modulation:
15%
Transponder Parameters
RF Modulation / ISO-MODE /
MOD
10%
RF Data coding ISO-MODE:
Fast (1/4) or Normal (1/256)
Timeslots ISO-MODE / NO-TS
1 or 16 Timeslots
ISO Option
– BREAK:
Complete Timeslot length at
„NO TAG“