OBID i-scan
®
System-Manual
ID ISC.LR200
FEIG ELECTRONIC GmbH
Page 102 of 174
H90692-16e-ID-B.doc
7.1.13. [0x2C] Get Multiple Block Security Status
This command reads the public block security status from one Transponder.
REQUEST-DATA
4
5
(6...13)
6 / (14)
7 / (15)
0x2C
MODE
UID
DB-ADR
DB-N
RESPONSE-DATA (STATUS = 0x95)
5
ISO15693-
ERROR
RESPONSE-DATA
5
6
DB-N
SEC-STATUS
Repeated
DB-N times
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
ADR
ADR:
b000
non-addressed
b001
addressed
b010
selected
UID:
Read-only serial number of the Transponder. The UID is required only in the addressed mode.
DB-ADR:
First block number from which security status is requested. First block number can be any
value between 0 and 255.
DB-N:
Number of Security data blocks to be read from the Transponder, starting at DB-ADR.
The maximum number of DB-N, depends on DB-Size.
DB-Size
Max. DB-N
4
0x20 ->32
8
0x10 ->16
x
= 128 / x
ISO15693-ERROR:
ISO15693 error code of Transponder response. This byte is only available if STATUS = 0x95.
SEC-STATUS:
Block security status .
Note:
This command is only available for ISO15693 Transponders.