OBID i-scan
®
System-Manual
ID ISC.LR200
FEIG ELECTRONIC GmbH
Page 123 of 174
H90692-16e-ID-B.doc
7.2.5.
ST Microelectronics Custom Commands
7.2.5.1. [0xA0] Activate EAS
This command sets the EAS bit to 1.
REQUEST-DATA
5
6
(7-14)
0xA0
MODE
UID
RESPONSE-DATA (STATUS = {0x95})
5
ISO-ERROR
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
-
-
-
-
-
ADR
ADR:
ADR
b000
non-addressed
b001
addressed
b010
selected
UID:
Read-only serial no. of the transponder. The UID is required only in the addressed mode.
ISO-ERROR: