OBID i-scan
®
System-Manual
ID ISC.LR200
FEIG ELECTRONIC GmbH
Page 161 of 174
H90692-16e-ID-B.doc
ANNEX D: Index of Status Bytes
Hex-value
General
0x00
OK:
•
Data / parameters have been read or stored without error
•
Control command has been executed
Hex-value
Transponder Status
0x01
No Transponder:
•
No Transponder is located within the detection field of the Reader.
•
The Transponder in the detection field has been switched to mute .
•
The communication between Reader and Transponder has been interfered and
the Reader is not able to read the Transponder anymore.
0x02
Data False:
•
CRC16 data error on received data.
0x03
Write-Error:
Negative plausibility check of the written data:
•
Attempt to write on a read-only storing-area (only I-Code 1 and Tag-it-HF
Transponders)
•
Too much distance between Transponder and Reader antenna.
•
Attempt to write in a noisy area.
0x04
Address-Error:
The required data are outside of the logical or physical Transponder-address area:
•
The address is beyond the max. address space of the Transponder.
•
The address is beyond the configured address space of the Transponder.
0x05
Wrong Transponder-type:
This command is not applicable at the Transponder:
•
A special command is not applicable to the Transponder.