OBID i-scan
®
System-Manual
ID ISC.LR200
FEIG ELECTRONIC GmbH
Page 162 of 174
H90692-16e-ID-B.doc
Hex-value
Parameter Status
0x10
EEPROM-Failure:
•
The EEPROM of the Reader is not able to be written on.
•
Before writing onto the EEPROM a faulty checksum of parameters has been
detected.
0x11
Parameter-Range-Error:
•
The value range of the parameters was exceeded.
0x13
Login-Request:
•
Configuration access without having logged in to the Reader before.
0x14
Login-Error:
•
Login attempt with wrong password.
0x15
Read Protect:
•
The configuration block is reserved for future use.
0x16
Write Protect:
•
The configuration block is reserved for future use.
0x17
Firmware activation required:
The firmware must be activated first using ISOStart demo program and the command “Set
Firmware Upgrade”. The update code must be ordered by Feig Electronic.
1. Read the Device-ID using the command [0x66] Get Reader Info (Mode 0x80)
2. Send the Device-ID and the serial number of the reader to Feig Electronic
3. Write the upgrade code into the reader using the command [0x5F] Set Firmware Update
Hex-value
Interface Status
0x80
Unknown Command:
•
The Reader does not support the selected function.
0x81
Length-Error:
•
The selected function has the wrong number of parameters.
0x82
Command not available:
•
A ISO15693 Host command was sent to the Reader in the Buffered Read or
Scan Mode.
•
A Buffered Read Mode protocol was sent to the Reader in the standard mode
•
The command with More bit does not correspond with the last command