OBID i-scan
®
System-Manual
ID ISC.LR200
FEIG ELECTRONIC GmbH
Page 169 of 174
H90692-16e-ID-B.doc
Config Block 0:
This config block activates protective functions of the Transponder .
The bits can be set only to 0 and never be reversed to 1. If block C0 is set into write protected state, no
further protective functions can be activated (hardware write protected state).
Bit
Byte
Function
Operation
Block I-Scan
Block I-Code 1
0
0
”1” = r/w, ”0” = ro
D0
5
1
"1" = r/w, ”0” = ro
D1
6
2
"1" = r/w, ”0” = ro
D2
7
3
"1" = r/w, ”0” = ro
D3
8
4
”1” = r/w, ”0” = ro
D4
9
5
"1" = r/w, ”0” = ro
D5
10
6
"1" = r/w, ”0” = ro
D6
11
7
"1" = r/w, ”0” = ro
D7
12
8
1
"1" = r/w, ”0” = ro
D8
13
9
"1" = r/w, ”0” = ro
D9
14
10
”1” = r/w, ”0” = ro
D10
15
11
-
-
-
12
-
-
-
13
-
-
-
14
-
-
-
15
-
-
-
16-23
2
-
-
-
24
3
-
-
-
25
-
-
-
26
-
-
-
27
”1” = r/w, ”0” = ro
C2
4
28
”1” = r/w, ”0” = ro
C1
3
29
"1" = r/w, ”0” = ro
C0
2
30
”0” = ro
S-NO
1
31
”0” = ro
S-NO
0