Config Block 1:
Special functions (EAS / QUIET-Mode) can be enabled by config block 1.
If EAS (Electronic Article Surveillance) mode is enabled, all Transponders will answer to an EAS
command.
If QUIET mode is enabled, the Transponder is permanently disabled. It can be activated with a „Reset
QUIET bit“ command. The I-Code 1 Transponder does not response to any command with exception of
the EAS command.
Bit
Byte
Function
0
0
"1”: EAS enable
"0”: EAS disable
1
"1": QUIET-Mode enable
"0": QUIET-Mode disable
2-7
-
8-15
1
-
16-23
2
-
24-31
3
-
Bits 2-31 are reserved for future use and will be set to „0“
Config Block 2:
Config block 2 can be used to define the family code and the application ID.
This feature offers the possibility to create „Transponder families“ and are only enabled if they are not
equal to zero (see chapter).
Bit
Byte
Function
0-7
0
Family Code
8-15
1
Application ID
16-23
2
-
24-31
3
-
Bits 16 - 31 can be used for user data without restriction.