OBID i-scan
®
System-Manual
ID ISC.LR200
FEIG ELECTRONIC GmbH
Page 30 of 174
H90692-16e-ID-B.doc
TRANS-FORM
3
:
By means of this byte, several parameters for the data transmission format of the
asynchronous interface can be defined.
Bit:
7
6
5
4
3
2
1
0
Function:
0
0
0
0
S
D
P
P:
Kind of Parity
b00:
no parity
b01:
even parity
b10:
odd parity
b11:
- do not use -
D:
Number of data bits
b0:
8 data bits
b1:
- do not use -
S:
Number of stop bits
b0:
1 stop bit
b1:
- do not use -
Note:
•
Changing of TRANS-FORM only becomes effective after writing / saving
configuration block CFG1 to EEPROM and reset of the Reader.
•
Always 8 Data Bits and 1 Stop Bits should be used
FLASH-LOADER-BAUD
1
:
By means of this byte the baud rate for the flash loader
4
can be defined.
0x06
9600 baud
0x07
19200 baud
0x08
38400 baud
3
A plausibility check is performed by writing this parameter to the Reader. If an error occurs the Reader answers
with STATUS = 0x11.
4
see: 5.2. [0x55] Start Flash Loader