OBID i-scan
®
System-Manual
ID ISC.LR200
FEIG ELECTRONIC GmbH
Page 35 of 174
H90692-16e-ID-B.doc
3.6. CFG5: RF-Interface III
The parameters of the CFG5 configuration block contain Transponder interface timing settings.
Byte
0
1
2
3
4
5
6
Contents
0x00
0x00
0x00
0x00
0x00
0x00
RF-MOD
Default
0x0F
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
RF-MOD:
RF Modulation in 10% Mode. A Range of 10%–30% (0x0A – 0x1E) is adjustable.
0x0A:
10% modulation
...
...
0x1E:
30% modulation
3.7. CFG6 + CFG7: Selection Mask (only I-Code EPC Transponder)
The I-Code EPC Transponder supports a selection feature in which groups of Transponders may be
selected. The parameters in these configuration blocks define the selection mask. Only the
Transponders in which the selection mask match with the serial number return their serial number.
CFG6:
Byte
0
1- 13
Contents
SELECTION
BITS
SELECTION
MASK MSB
SELECTION MASK
Default
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Byte
1 - 13
Contents
SELECTION MASK
Default
0x00
0x00
0x00
0x00
0x00
0x00
0x00
CFG7:
Byte
0-4
5
6
Contents
SELECTION MASK
SELECTION
MASK LSB
-
Default
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Byte
7
8
9
10
11
12
13
Contents
-
-
-
-
-
-
-
Default
0x00
0x00
0x00
0x00
0x00
0x00
0x00