OBID i-scan
®
System-Manual
ID ISC.LR200
FEIG ELECTRONIC GmbH
Page 48 of 174
H90692-16e-ID-B.doc
SYNC:
Selects the synchronization parameters.
Bit:
7
6
5
4
3
2
1
0
Function
RFOFF
SYNC SWITCH
CONDITION
0
0
0
MASTER
MODE
MODE:
b00:
Synchronization OFF
b01:
Synchronization ON
MASTER:
b0:
Slave
b1:
Master
SYNC SWITCH CONDITION:
b0:
After the anticollision process has been finished (no additional
response) or
at the latest after the TR-RESPONSE-TIMEOUT, the
reader sends the sync signal to the next reader.
b1:
reserved
RFOFF:
b0:
After the Reader has completed its task of RF Communication and passes
the control to the next Reader, the RF-field will not be switched off, only the
task
will
stopped.
b1:
After the Reader has completed its task of RF Communication and passes
the RF Communication to the next Reader, the RF-field will be switched off
Note:
One Reader in the synchronization chain must be configured as MASTER to
start the synchronization.
SYNC-TIMEOUT:
(0...65535 x 1 ms = 0 ms ... 65,535 sec)
Timeout between two synchronization pulses
Note:
If the reader doesn’t detect a synchronization pulse on the “IN1”within the SYNC-
TIMEOUT, the reader starts the RF communication automatically after the SYNC-
TIMEOUT.
In addition, the error message “0x85 Synchronization Error” appears.