OBID i-scan
®
System-Manual
ID ISC.LR200
FEIG ELECTRONIC GmbH
Page 51 of 174
H90692-16e-ID-B.doc
DB = data block
b0:
Output of a data field inactive
b1:
Output of a data field active
Setting this bit activates the output of a specified data field
ANT
(only for Multiplexer Mode)
b0:
the number of the antenna will not be stored
b1:
the number of the antenna (1-8) where the transponder has been detected,
will be stored.
Note:
If Multiplexer Mode is disabled the antenna number will be always 1
The number of the antenna will
The antenna number will only be transferred via asynchronous
interface, not via data clock interface.
TIME
b0:
Output of internal system timer inactive
b1
Output of internal system timer active
Setting this bit activates the output of the internal system timer
Internal system timer (see chapter 4.6. [0x85] Set System Timer for details).
COM Prefix
b0:
COM-ADR of the Reader will not transmit
b1:
COM-ADR of the Reader will transmit
When this option is on, the Reader will transmit the COM-ADR before each data set.
Byte Order
b0:
MSB first
b1:
LSB first
Defines the Byte Order within frame