OBID i-scan
®
System-Manual
ID ISC.LR200
FEIG ELECTRONIC GmbH
Page 59 of 174
H90692-16e-ID-B.doc
ONT:
Defines which Transponder will be send to the host.
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
0
0
ONT
ONT:
b0
all Transponders in the field will be send to the host
The Reader performs an RF Reset before any command reads a Serial
Number
b1
only the new selected Transponders will be sent to the host
3.14. CFG14: Reserved
The configuration block CFG14 is reserved for future use.
Byte
0
1
2
3
4
5
6
Contents
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default