OBID i-scan
®
System-Manual
ID ISC.LR200
FEIG ELECTRONIC GmbH
Page 82 of 174
H90692-16e-ID-B.doc
6. Special Commands
6.1. [0x1B] Reset QUIET Bit (only I-Code 1 Transponders)
This command resets the Quiet Bit of all I-Code 1 Transponders in the antenna field. After using this
command a Transponder once placed in QUIET mode is activated again. For activating the QUIET
mode in I-Code 1 Transponders see
ANNEX G: Memory Model I-Code 1
Transponders for details.
Host
→
Reader
1
2
3
4...5
5
COM-ADR
0x1B
CRC16
Host
←
Reader
1
2
3
4
5...6
6
COM-ADR
0x1B
STATUS
30
CRC16
6.2. [0x1C] EAS (only I-Code 1 Transponders)
This command sends an EAS request to the Transponder. If the EAS function of the Transponder is
active, the Transponder answers with a special EAS sequence. For this command a Transponder does
not need to be selected. Whether the Reader receives this sequence or not is shown to the host by
setting the status byte. The EAS level has to be set in the
3.4. CFG3: RF-Interface I
configuration
block. For enablilng the EAS function in I-Code 1 Transponders see
ANNEX G: Memory Model I-Code
1
Transponders for details.
Host
→
Reader
1
2
3
4...5
5
COM-ADR
0x1C
CRC16
Host
←
Reader
1
2
3
4
5...6
6
COM-ADR
0x1C
STATUS
1
CRC16
30
see ANNEX D: Index of Status Bytes