In countries where FCC approval is required, the ID ISC.MR100 reader may only be operated us-
ing the antenna listed in table. Changes or modifications, not expressly authorized by the relevant
approval body, may result in revocation of the user’s operating permission.
Article No.
Part No.
1663.000.00
ID ISC.ANT340/240
Table 7: Antennas with FCC Approval
Electrical connection, commissioning, maintenance, measurement and calibration work on
the unit is to be performed only by electrical specialists or persons with equivalent training.
3.5. Starting
The reader must be registered to the operating system by the first use.
To do this you should read the manual “Installation OBID USB-driver“.
3.5.1. ID ISC.MR100
For registering the reader to the operating system, the reader must be connected to the power
supply and the USB-cable. In which order the cables are connected will remain left to the user.
The reader should not be used without connected antenna. Due to the reader uses an external
power supply a “Low Powered Hub”-interface is sufficient. The maximum current through the USB-
Interface amounts to 100mA.
3.5.2. ID ISC.PR100
If the reader is connected with the USB-Interface of the computer by using an USB-cable, he reg-
isters in the operating system automatically. The power requirement of the reader amounts to
more than 100 mA. The USB-Interface must be a High Powered Hub. A High Powered Hub sup-
ports the reader up to 500mA.
Note:
The function of the reader is only guaranteed if it is connected to a High Powered Hub.