OBID i-scan
®
System-Manual
ID ISC.MR/PR/PRH101
FEIG ELECTRONIC GmbH
Page 10 of 131
H60301-3e-ID-B.doc
1. Data Transmission between OBID
®
i-scan ID ISC.MR/PR/PRH101 and Host
Four different ways of data transmission between OBID
®
i
-scan
Readers and host (terminal, PC) are
possible. The
ISO15693Host Commands
and the
Scan Mode
are used for the data exchange be-
tween Transponder and host, whereas the
Configuration Commands
and the
Control
serves for
adapting the Reader parameters to the individual range of applications. The following chart shows
which method of data transmission is supported by which interface:
asynchronous interface
(RS232 / RS485)
Configuration Commands
√
Control Commands
√
ISO15693Host Commands
√
Scan-Mode
√
1.1. Configuration Commands and Control Commands
This method of data transmission is used for Reader configuration and the diagnosis via the asyn-
chronous interface or USB.
The Reader-configuration parameters will be stored in the Reader memory. To store the current con-
figuration during a power down of the Reader, the Reader-Configuration must be stored in the
EEPROM. After power up the Reader reads the configuration out of the EEPROM.
The Reader control is immediately processed and the response from the Reader contain status or
data information of the control command.
Host (Terminal / PC / ....)
Reader
parameter- / control command
→
parameter received and stored / control
command processed
yes
no
←
status /
data
error status
←