9.1.10. Texas Instruments (Tag-it
™
HF-I Plus)
The command codes listed in the following table support the various Transponder commands and
operations that are available for Tag-it
™
HF-I PlusTransponders.
IC manufacturer identifier: 0x07
Product ID / Config : (xxxx / nnn)
Tag-it
™
HF-I Plus
= b0000 000 or
= b1000 000
Memory organization: 64 x 4 Byte = 2kBit user data
Number of blocks
65 (user area: 0...63)
Block size
4 byte
Command
Code
Function
Mode
Comment
non-ad-
dressed
addressed
select
0x01
Inventory
√
-
-
-
0x02
Stay Quiet
√
-
√
-
0x22
Lock Block
√
√
√
√
WR-OPTION = 1
**
0x23
Read Multiple Blocks
√
√
√
√
DB-Size = 4
WR-OPTION = 1
**
0x24
Write Multiple Blocks
-
-
-
-
0x25
Select
√
-
√
-
0x26
Reset to Ready
√
√
√
√
0x27
Write AFI
√
√
√
√
WR-OPTION = 1
**
0x28
Lock AFI
√
√
√
√
WR-OPTION = 1
**
0x29
Write DSFID
√
√
√
√
WR-OPTION = 1
**
0x2A
Lock DSFID
√
√
√
√
WR-OPTION = 1
**
0x2B
Get System Information
√
√
√
√
0x2C
Get Multiple Block Security
Status
√
√
√
√
Custom specific commands
0xA2
Write_2_Blocks
√
√
√
√
0xA3
Lock_2_Blocks
√
√
√
√
**
The WR-OPTION will be set automatically by the FEIG Readers if the WR-OPTION parameter
in “CFG4 General Transponder Param” is set to “00: automatically set” (
3.5. CFG4:
Transponder Parameters
).
By using the “non-addressed ” mode the WR-OPTION must be set manually to “WR-
OPTION = 1”.
Note: