Hex-value
Parameter Status
0x10
EEPROM-failure:
•
The EEPROM of the Reader is not able to be written on.
•
Before writing onto the EEPROM a faulty checksum of parameters has been detected.
0x11
Parameter-Range-Error:
•
The value range of the parameters was exceeded.
0x17
Firmware activation required:
•
The firmware must be activated first using ISOStart demo program and the command “Set
Firmware Upgrade”. The update code must be ordered by Feig Electronic.
1. Read the Device-ID using the command [0x66] Get Reader Info (Mode 0x80)
2. Send the Device-ID and the serial number of the reader to Feig Electronic
3. Write the upgrade code into the reader using the command [0x5F] Set Firmware Up-
date
Hex-value
Interface Status
0x80
Unknown Command:
•
The Reader does not support the selected function.
0x81
Length-Error:
•
Protocol is too short or too long
0x82
Command not available:
•
0x83
RF communication error:
This error indicates that there is an error in communication between the Transponder
and the Reader. Reason for this can be:
•
The collision handling algorithm was not continued until no collision is detected, reasons
for the break:
- TR-RESPOSE-TIME in CFG1 Interface is too short
0x94
More Data:
•
There are more Transponder data sets requested than the response protocol can transfer
at once.
0x95
ISO 15693 Error:
•
An additional error code for ISO15693 Transponders is sent with response data.