SCAN-LOCK-TIME:
(1 ... 65535 * 100 ms = 100 ms ... 6553,5 sec)
The SCAN-LOCK-TIME defines the period in which the Reader does not transmit the Trans-
ponder data a second time, after it has transmitted it the first time. (regardless whether the
Transponder is in the detection range of the reader during SCAN-LOCK-TIME or not). The
SCAN-LOCK-TIME starts after the data transmission from the Transponder to the Reader.
Transponder in field
SCAN-LOCK-TIME
Data output
t
r
:
Time to read the Transponder data
t
o
:
Data Transmission from the Reader to the host
t
s
:
SCAN-LOCK-TIME
As long as the SCAN-LOCK-TIME is active, the Transponder can be in the detection
range of the reader or outside of it.
DB-ADR:
Transponder address of the first data block which will be transferred in Scan-Mode.
Range: 0x00...0xFF.
See for valid addresses:
ANNEX G: Memory Model I-Code 1 Transponders
and
9.1. Suppor-
ted ISO15693 Host commands for ISO15693
Transponders
D-LGT:
D-LGT defines the length of raw data which are transmitted in the Scan-Mode.
Number of
data bytes
to be transferred, starting with the D-START.
Example:
data block
Byte
0
1
2
3
4
5
6
7
Data
0x01
0x23
0x45
0x67
0x89
0xAB
0xCD
0xEF
Output Data
0x23
0x45
0x67
0x89
D-START = 1
D-LGT = 4
start of read
t
r
t
r
t
o
t
s
t
o
t
s